Advertisement

Force Profiles of Single Ventricle Atrioventricular Leaflets in Response to Annular Dilation and Leaflet Tethering

Published:November 28, 2022DOI:https://doi.org/10.1053/j.semtcvs.2022.09.012
      We sought to understand how leaflet forces change in response to annular dilation and leaflet tethering (LT) in single ventricle physiology. Explanted fetal bovine tricuspid valves were sutured onto image-derived annuli and ventricular mounts. Control valves (CON) were secured to a size-matched hypoplastic left heart syndrome (HLHS)-type annulus and compared to: (1) normal tricuspid valves secured to a size-matched saddle-shaped annulus, (2) HLHS-type annulus with LT, (3) HLHS-type annulus with annular dilation (dilation valves), or (4) a combined disease model with both dilation and tethering (disease valves). The specimens were tested in a systemic heart simulator at various single ventricle physiologies. Leaflet forces were measured using optical strain sensors sutured to each leaflet edge. Average force in the anterior leaflet was 43.2% lower in CON compared to normal tricuspid valves (P < 0.001). LT resulted in a 6.6% increase in average forces on the anterior leaflet (P = 0.04), 10.7% increase on the posterior leaflet (P = 0.03), and 14.1% increase on the septal leaflet (P < 0.001). In dilation valves, average septal leaflet forces increased relative to the CON by 42.2% (P = 0.01). In disease valves, average leaflet forces increased by 54.8% in the anterior leaflet (P < 0.001), 37.6% in the posterior leaflet (P = 0.03), and 79.9% in the septal leaflet (P < 0.001). The anterior leaflet experiences the highest forces in the normal tricuspid annulus under single ventricle physiology conditions. Annular dilation resulted in an increase in forces on the septal leaflet and LT resulted in an increase in forces across all 3 leaflets. Annular dilation and LT combined resulted in the largest increase in leaflet forces across all 3 leaflets.

      Graphical Abstract

      Keywords

      Abbreviations:

      AV (atrioventricular valve), CO (cardiac output), CON (control valve), NTV (normal tricuspid valve), LT (leaflet tethering valve), DIL (dilation valve), DIS (disease valve), HLHS (hypoplastic left heart syndrome), HR (heart rate), MAP (mean arterial pressure), RV (right ventricle), SCP (septal circumferential percentage), SV (single ventricle), SVP (single ventricle physiology), TR (tricuspid regurgitation), TV (tricuspid valve)
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to Seminars in Thoracic and Cardiovascular Surgery
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • King G
        • Ayer J
        • Celermajer D
        • et al.
        Atrioventricular valve failure in fontan palliation.
        J Am Coll Cardiol. 2019; 73: 810-822
        • Ohye RG.
        Multi-Institutional studies: Lessons learned from the pediatric heart network single ventricle reconstruction trial.
        Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu. 2010; 13: 76-78
        • Newburger Jane W.
        • Sleeper Lynn A.
        • William Gaynor J.
        • et al.
        Transplant-Free survival and interventions at 6 years in the SVR trial.
        Circulation. 2018; 137: 2246-2253
        • Honjo O
        • Atlin CR
        • Mertens L
        • et al.
        Atrioventricular valve repair in patients with functional single-ventricle physiology: Impact of ventricular and valve function and morphology on survival and reintervention.
        J Thorac Cardiovasc Surg. 2011; 142 (e2): 326-335
        • Stamm C.
        The morphologically tricuspid valve in hypoplastic left heart syndrome.
        Eur J Cardio-Thorac Surg. 1997; 12: 587-592
        • Dreyfus GD
        • Corbi PJ
        • Chan KMJ
        • et al.
        Secondary tricuspid regurgitation or dilatation: Which should be the criteria for surgical repair?.
        Ann Thorac Surg. 2005; 79: 127-132
        • Alsoufi B
        • Sinha R
        • McCracken C
        • et al.
        Outcomes and risk factors associated with tricuspid valve repair in children with hypoplastic left heart syndrome.
        Eur J Cardio-Thorac Surg. 2018; 54: 993-1000
        • Stephens EH
        • Dearani JA
        • Niaz T
        • et al.
        Effect of earlier atrioventricular valve intervention on survival after the Fontan operation.
        Am J Cardiol. 2020; 137: 103-110
        • Ricci M
        • Lombardi P
        • Galindo A
        • et al.
        Distribution of cardiac output and oxygen delivery in an acute animal model of single-ventricle physiology.
        J Thorac Cardiovasc Surg. 2005; 130: 1062-1070
        • Fukuda S
        • Saracino G
        • Matsumura Y
        • et al.
        Three-dimensional geometry of the tricuspid annulus in healthy subjects and in patients with functional tricuspid regurgitation: A real-time, 3-dimensional echocardiographic study.
        Circulation. 2006; 114: 1492-1498
      1. Hypoplastic left heart syndrome.
        Congenital Heart Defects. Steinkopff, 2009: 122-129
        • Mauger C
        • Gilbert K
        • Lee AM
        • et al.
        Right ventricular shape and function: cardiovascular magnetic resonance reference morphology and biventricular risk factor morphometrics in UK Biobank.
        J Cardiovasc Magn Reson. 2019; 21: 41
        • Kutty S
        • Colen T
        • Thompson RB
        • et al.
        Tricuspid regurgitation in hypoplastic left heart syndrome: Mechanistic insights from 3-dimensional echocardiography and relationship with outcomes.
        Circ Cardiovasc Imaging. 2014; 7 (Epub 2014 Jul 29): 765-772https://doi.org/10.1161/CIRCIMAGING.113.001161
        • Paulsen MJ
        • Kasinpila P
        • Imbrie-Moore AM
        • et al.
        Modeling conduit choice for valve-sparing aortic root replacement on biomechanics with a 3-dimensional–printed heart simulator.
        J Thorac Cardiovasc Surg. 2019; 158: 392-403
        • Cattermole GN
        • Leung PYM
        • Ho GYL
        • et al.
        The normal ranges of cardiovascular parameters measured using the ultrasonic cardiac output monitor.
        Physiol Rep. 2017; 5: e13195
        • Fleming S
        • Thompson M
        • Stevens R
        • et al.
        Normal ranges of heart rate and respiratory rate in children from birth to 18 years of age: A systematic review of observational studies.
        Lancet. 2011; 377: 1011-1018
        • Paulsen MJ
        • Bae JH
        • Imbrie-Moore AM
        • et al.
        Development and ex vivo validation of novel force-sensing Neochordae for measuring Chordae Tendineae tension in the mitral valve apparatus using optical fibers with embedded Bragg gratings.
        J Biomech Eng. 2020; 142: 0145011-9
        • Pant AD
        • Thomas VS
        • Black AL
        • et al.
        Pressure-induced microstructural changes in porcine tricuspid valve leaflets.
        Acta Biomaterialia. 2018; 67: 248-258
        • Jett SV
        • Hudson LT
        • Baumwart R
        • et al.
        Integration of polarized spatial frequency domain imaging (pSFDI) with a biaxial mechanical testing system for quantification of load-dependent collagen architecture in soft collagenous tissues.
        Acta Biomaterialia. 2020; 102: 149-168
        • Mathur M
        • Jazwiec T
        • Meador WD
        • et al.
        Tricuspid valve leaflet strains in the beating ovine heart.
        Biomech Model Mechanobiol. 2019; 18: 1351-1361https://doi.org/10.1007/s10237-019-01148-y
        • Kong F
        • Pham T
        • Martin C
        • et al.
        Finite element analysis of tricuspid valve deformation from multi-slice computed tomography images.
        Ann Biomed Eng. 2018; 46: 1112-1127
        • Dolensky JR
        • Casa LDC
        • Siefert AW
        • et al.
        In vitro assessment of available coaptation area as a novel metric for the quantification of tricuspid valve coaptation.
        J Biomech. 2013; 46: 832-836
        • Troxler LG
        • Spinner EM
        • Yoganathan AP.
        Measurement of strut chordal forces of the tricuspid valve using miniature C ring transducers.
        J Biomech. 2012; 45: 1084-1091
        • Meador WD
        • Mathur M
        • Sugerman GP
        • et al.
        A detailed mechanical and microstructural analysis of ovine tricuspid valve leaflets.
        Acta Biomater. 2020; 102: 100-113
        • Ton-Nu TT
        • Levine RA
        • Handschumacher MD
        • et al.
        Geometric determinants of functional tricuspid regurgitation: Insights from 3-dimensional echocardiography.
        Circulation. 2006; 114: 143-149
        • Spinner Erin M.
        • Patrick Shannon
        • Dana Buice
        • et al.
        In vitro characterization of the mechanisms responsible for functional tricuspid regurgitation.
        Circulation. 2011; 124: 920-929